Commercial Barrier Arms

Versatile use and reliable vehicle barriers.

AXpark barriers are all-rounders suitable for a variety of applications, such as parking lots, parking garages, company premises, gated communities or all other areas where reliable control of vehicle access is desirable.

AX-PARK

Highly reliable with a range of functions for flexibilty.

Very fast opening times of as little as 1.3 seconds make the AXpark the perfect solution for use in highly frequented parking garages. It can be installed with boom lengths of up to 20 ft, so that even very wide vehicle entrances can be controlled by this flexible system.

Good connectivity via ethernet tcp/ip, w-lan.

AXpark barriers are provided with various interfaces to work with present and future control technologies, so that the barrier can be operated remotely using protocols such as Ethernet TCP/IP.

Low operating costs, high quality components.

Up-to-date controls, a robust mechanism and a low-wear, heavy-duty servo drive are all combined in a barrier of the best possible quality. Its extremely low power consumption and minimum maintenance costs complete the picture.

AXpark Models Comparison Chart

MODELP1300P4000P6000
DescriptionBarriers with lane
width up to 12 ft.
Opening and
closing speed can
be set to 1.3 s, 1.8 s
and 2.5 s.
Barriers with lane
width up to 20 ft.
Opening and
closing speed can
be set to 4 s, 6 s
and 8 s.
Barriers with lane
width up to 28 ft.
Opening and
closing speed can
be set to 6 s, 9 s
and 12 s.
Lane widthUp to 12 ft.Up to 20 ft.Up to 28 ft.
Actuation time1.3 s / 1.8 s / 2.5 s4 s / 6 s / 8 s6 s / 9 s / 12 s
Power consumptionMax. 90 WMax. 90 WMax. 25 W
Ingress protectionIP 54IP 54IP 54
Weightapprox. 110 lbsapprox. 110 lbs265 lbs
Dimensions (WxDxH)12.9x12.9x39 in.12.9x12.9x39 in.14.1x16.4x39 in.
Specified opening/- closing cycles10 Million10 Million5 million
Duty cycle100%100%100%
Wind load class *43 resp. 44
Temperature range-22° to +131° F-22° to +131° F-22° to +131° F
Power supply100 - 240 V AC; 50-60 Hz100 - 240 V AC; 50-60 Hz100 - 240 V AC; 50-60 Hz
Drive unitServoDriveServoDriveServoDrive
Drive voltageProtective low voltage 24 V DCProtective low voltage 24 V DCProtective low voltage 24 V DC
* The wind load class is reduced when using accessories on the barrier boom. (All data is provided to the best of our knowledge and awareness and is subject to error and amendment.)